www.estevezbooks.com 

*** LOS PRECIOS MARCADOS ESTAN REFERIDOS EN USD, PARA PRECIOS EN PESOS MEXICANOS. UTILIZAR PARIDAD DE CAMBIO USD A MN DE DOF O CONSULTAR AL TEL 0155 5676 4480  o 0155 3187 2918  aestevez@prodigy.net.mx ***

Power Factor Correction & Harmonics & Your Electric Bill . .-Ed. EC & M.- 2001.- 92 p.-
Precio en Pesos: $0.00
Precio en Dolares: $35.00
Idioma: Ingles
Numero de Articulo:ECM7715

EC&M's Practical Guide to Power Factor Correction & Harmonics…and Your Electric Bill

EC&M's Practical Guide to Power Factor Correction & Harmonics…and Your Electric Bill

ISBN 087288 7715  87 PAG.

Large electrical utility customers strive to reduce their electrical utility bill. One common way of doing this is to reduce the peak kVA demand by correcting the system power factor. While this works well where electrical harmonic-producing loads are connected to the electrical system the installation of power factor correction capacitors can cause both overvoltage and overcurrent failures. Preventing these costly failures while correcting the system power factor must be done in an exacting manner that is detailed in this book. This book highlights the design items to be considered, provides explanations, and gives many worked out examples of types of design problems that must be considered.

 

CONTENTS

 

CHAPTER 1

THE ELECTRICAL POWER CIRCUIT

 

CHAPTER 2

ELECTRICAL HARMONICS (AND WHWERE HARMONIC CURRENTS FLOW)

 

CHAPTER 3

THE IMPACT OF HARMONICS ON ELECTRICAL EQUIPMENT

 

CHAPTER 4

POWER CALCULATIONS WHERE HARMONICS MUST BE CONSIDERED

 

CHAPTER 5

HARMONIC VOLTAGE AND HARMONIC CURRENT –HOW MUCH IS TOO MUCH?

 

CHAPTER 6

UNDERSATNDING THE RESONANT CIRCUIT

 

CHAPTER 7

HARMONICS AND THE ELECTRICAL POWER SYSTEM

 

CHAPTER 8

REDUCING HARMONIC CURRENTS

 

CHAPTER 9

HARMONICS SYSTEM ANALYSIS

 

CHAPTER 10

HARMONIC RESONANCE

 

CHAPTER 11

“STEP” CONSTRUCTION OF CAPACITOR BANKS

 

CHAPTER 12

POWER FACTOR AND YOUR ELECTRICAL UTILITY BILL

 

CHAPTER 13

THE SITE SURVEY

 

CHAPTER 14

THE TYPICAL STEP-BY-STEP PROCEDURE OF A POWER FACTOR CORRECTION PROJECT

 

CHAPTER 15

A SUMMARY- PUTTING AT ALL TOGETHER

 

CHAPTER 16

BONUS CHAPTER- THE PASSIVE HARMONIC FILTER

 

Mayor Información

Si desea ordenar alguno de estos productos, comuniquese con nosotros al telefono (55) 5676-4480 y (55) 3187-2918, fax (55) 5676-9558 en la Cd. de Mexico, o envienos un mensaje a  la siguiente direccion:  aestevez@prodigy.net.mx  
 

Gracias.

 

Dudas o comentarios sobre este sitio:  aestevez@prodigy.net.mx  
Ultimo cambio: October 14, 2008